Truth Toomey ‘Allo’ Glass Syringes Allo base Tip without Nozzle 150ml, (Pack of 1)
- Stock: In Stock
- Model: 18-16-00-08
- Weight: 0.10kg
- SKU: 18-16-00-08
Short Description
- Toomey ‘Allo’ Syringe with Nozzle has a metal Adapter which is reinforced in the glass barrel with Metal plunger.
- TRÜTH ‘Richard Wolf’ Bladder Glass Syringes has metal adapter which is reinforced in the glass barrel.
- Compatible with endoscopes of ‘KARL STORZ’
- Custom made adaptors can also be made available upon request.
- Suitable for endoscopic attachment for post operative aspiration.
- As per ‘KARL STORZ’ article no 822.40-150m.
- These syringes are suitable for endoscopic attachment.
- Bladder Glass Syringes has metal adapter which is reinforced in the glass barrel.
- Standard adapters are compatible with endoscopes of Wolf.
TRÜTH Toomey ‘Allo’ Syringe without Nozzle has a metal Adapter which is reinforced in the glass barrel with Metal plunger. Standard adapters are compatible with the endoscopes of ‘KARL STORZ’.
Used for Post-Operative Aspiration as mentioned in Endoscope Reprocessing Guides especially flexible Endoscopes consisting.
Custom-made adapters can also be made available upon request.
Suitable for endoscopic attachment for postoperative aspiration.
As Per ‘KARL STORZ’ Article no 27211LO-50ml, 27212LO-100ml.
Used for Post-Operative Aspiration as mentioned in Endoscope Reprocessing Guides consisting of the following steps:
• Pre-cleaning
• Manual Cleaning
• Rinsing
• High-Level Disinfection
• Re-Rinsing &
• Drying
• OEM on request
Brief Points for Cleaning the Toomey ‘Allo’ & Bladder Glass Syringes.
• Cleaning agents with neutral PH between 6.0 – 8.0 are recommended.
• Do not process glass syringes with other manufacturer products.
• Universal accepted precautions for handling contaminated / bio-hazardous materials should be observed.
• Remove excess body fluids and tissues. Flush and rinse using running water.
• Soak and Pre-Cleaning prior to cleaning.
• Completely submerge the instrument in a neutral PH enzyme solution and flush vigorously. Ensure effective pre- cleaning.
• Immerse in a neutral PH ( 6.0-8.0 ) cleaning agent solution.
• Ensure medical devices are visibly to remove residual solution.
• Do not pile devices on top of each other.
• Sonicate medical devices.
• Rinse medical devices to remove residual solution.
• Check for the Damaged or worn parts or organic matter.
• All medical devices should be drip dried for several minutes before sterilization preparations.
• Wrap medical devices in a medically approved sterilization wrap.
• Autoclave.
• After sterilization, medical devices should remain in sterilization
wrap or sterilization containers and stored in a clean dry environment.
Syringe | |
Liquid Path | Borosilicate Glass, Ni-cr chrome plated brass |
Size | 150ML |
Sterility | Non sterile |
Termination | Metal Base Tip |
Autoclavable | Yes |
Graduation | 2ml |
Graduation Type | Permanently Fused |
Volume Variation | ± 4% |